Comparison of Glass Fragments Using Particle-Induced X-Ray Emission (PIXE) Spectrometry
Document Type
Article
Publication Date
3-2011
Publication Source
Journal of Forensic Sciences
Volume Number
56
Issue Number
2
First Page
366
Last Page
371
Publisher
WILEY-BLACKWELL
ISSN
0022-1198
Abstract
A procedure has been developed to analyze the trace element concentrations in glass fragments using particle-induced X-ray emission (PIXE) spectrometry. This method involves using accelerated protons to excite inner-shell electronic transitions of target atoms and recording the resultant X-rays to characterize the trace element concentrations. The protocol was able to identify those glass fragments that originated from different sources based on their elemental analyses. The protocol includes specific approaches to calculating uncertainties and handling measurements below the level of detection. The results indicate that this approach has increased sensitivity for several elements with higher atomic number compared with X-ray fluorescence methods. While not as sensitive as laser-ablation or inductively coupled plasma mass spectrometry methods of dissolved samples, it is entirely nondestructive and entails a much simpler sample preparation process that may be used to presort glass fragments for more comprehensive elemental analysis. As such, the technique described may have a niche role in forensic glass analysis.
Recommended Citation
Published in: Journal of Forensic Sciences, Volume 56, Issue 2, March 1, 2011, pages 366-371. Copyright © 2011 WILEY-BLACKWELL, Malden, MA. The final published version is available at: http://dx.doi.org/10.1111/j.1556-4029.2010.01650.x